PXA3xx GCU Controller
|
|
---------------------
|
|
|
|
Required properties:
|
|
- compatible : "marvell,pxa300-gcu"
|
|
- reg : should contain the register range (address and length).
|
|
- interrupts : Controller interrupt.
|
|
- clocks: phandle to the PXA specific input clock.
|
|
|
|
Example for PXA300:
|
|
|
|
display-controller@54000000 {
|
|
compatible = "marvell,pxa300-gcu";
|
|
reg = <0x54000000 0x1000>;
|
|
interrupts = <39>;
|
|
clocks = <&clks CLK_PXA300_GCU>;
|
|
};
|