# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
|
|
%YAML 1.2
|
|
---
|
|
$id: http://devicetree.org/schemas/power/supply/battery.yaml#
|
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
|
|
|
title: Battery Characteristics
|
|
|
|
maintainers:
|
|
- Sebastian Reichel <sre@kernel.org>
|
|
|
|
description: |
|
|
The devicetree battery node provides static battery characteristics.
|
|
In smart batteries, these are typically stored in non-volatile memory
|
|
on a fuel gauge chip. The battery node should be used where there is
|
|
no appropriate non-volatile memory, or it is unprogrammed/incorrect.
|
|
|
|
Upstream dts files should not include battery nodes, unless the battery
|
|
represented cannot easily be replaced in the system by one of a
|
|
different type. This prevents unpredictable, potentially harmful,
|
|
behavior should a replacement that changes the battery type occur
|
|
without a corresponding update to the dtb.
|
|
|
|
Battery properties are named, where possible, for the corresponding elements
|
|
in enum power_supply_property, defined in include/linux/power_supply.h
|
|
|
|
Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
|
|
The phandle's property should be named "monitored-battery".
|
|
|
|
properties:
|
|
compatible:
|
|
const: simple-battery
|
|
|
|
device-chemistry:
|
|
description: This describes the chemical technology of the battery.
|
|
oneOf:
|
|
- const: nickel-cadmium
|
|
- const: nickel-metal-hydride
|
|
- const: lithium-ion
|
|
description: This is a blanket type for all lithium-ion batteries,
|
|
including those below. If possible, a precise compatible string
|
|
from below should be used, but sometimes it is unknown which specific
|
|
lithium ion battery is employed and this wide compatible can be used.
|
|
- const: lithium-ion-polymer
|
|
- const: lithium-ion-iron-phosphate
|
|
- const: lithium-ion-manganese-oxide
|
|
|
|
over-voltage-threshold-microvolt:
|
|
description: battery over-voltage limit
|
|
|
|
re-charge-voltage-microvolt:
|
|
description: limit to automatically start charging again
|
|
|
|
voltage-min-design-microvolt:
|
|
description: drained battery voltage
|
|
|
|
voltage-max-design-microvolt:
|
|
description: fully charged battery voltage
|
|
|
|
energy-full-design-microwatt-hours:
|
|
description: battery design energy
|
|
|
|
charge-full-design-microamp-hours:
|
|
description: battery design capacity
|
|
|
|
trickle-charge-current-microamp:
|
|
description: current for trickle-charge phase
|
|
|
|
precharge-current-microamp:
|
|
description: current for pre-charge phase
|
|
|
|
precharge-upper-limit-microvolt:
|
|
description: limit when to change to constant charging
|
|
|
|
charge-term-current-microamp:
|
|
description: current for charge termination phase
|
|
|
|
constant-charge-current-max-microamp:
|
|
description: maximum constant input current
|
|
|
|
constant-charge-voltage-max-microvolt:
|
|
description: maximum constant input voltage
|
|
|
|
factory-internal-resistance-micro-ohms:
|
|
description: battery factory internal resistance
|
|
|
|
resistance-temp-table:
|
|
$ref: /schemas/types.yaml#/definitions/uint32-matrix
|
|
items:
|
|
items:
|
|
- description: the temperature in degree Celsius
|
|
- description: battery internal resistance percent
|
|
description: |
|
|
A table providing the temperature in degree Celsius
|
|
and corresponding battery internal resistance percent, which is used to
|
|
look up the resistance percent according to current temperature to get an
|
|
accurate batterty internal resistance in different temperatures.
|
|
|
|
ocv-capacity-celsius:
|
|
description: |
|
|
An array containing the temperature in degree Celsius,
|
|
for each of the battery capacity lookup table.
|
|
|
|
operating-range-celsius:
|
|
description: operating temperature range of a battery
|
|
items:
|
|
- description: minimum temperature at which battery can operate
|
|
- description: maximum temperature at which battery can operate
|
|
|
|
ambient-celsius:
|
|
description: safe range of ambient temperature
|
|
items:
|
|
- description: alert when ambient temperature is lower than this value
|
|
- description: alert when ambient temperature is higher than this value
|
|
|
|
alert-celsius:
|
|
description: safe range of battery temperature
|
|
items:
|
|
- description: alert when battery temperature is lower than this value
|
|
- description: alert when battery temperature is higher than this value
|
|
|
|
required:
|
|
- compatible
|
|
|
|
patternProperties:
|
|
'^ocv-capacity-table-[0-9]+$':
|
|
$ref: /schemas/types.yaml#/definitions/uint32-matrix
|
|
description: |
|
|
An array providing the open circuit voltage (OCV)
|
|
of the battery and corresponding battery capacity percent, which is used
|
|
to look up battery capacity according to current OCV value. And the open
|
|
circuit voltage unit is microvolt.
|
|
maxItems: 100
|
|
items:
|
|
items:
|
|
- description: open circuit voltage (OCV) in microvolts
|
|
- description: battery capacity percent
|
|
maximum: 100
|
|
|
|
additionalProperties: false
|
|
|
|
examples:
|
|
- |
|
|
power {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
battery: battery {
|
|
compatible = "simple-battery";
|
|
over-voltage-threshold-microvolt = <4500000>;
|
|
re-charge-voltage-microvolt = <250000>;
|
|
voltage-min-design-microvolt = <3200000>;
|
|
voltage-max-design-microvolt = <4200000>;
|
|
energy-full-design-microwatt-hours = <5290000>;
|
|
charge-full-design-microamp-hours = <1430000>;
|
|
precharge-current-microamp = <256000>;
|
|
precharge-upper-limit-microvolt = <2500000>;
|
|
charge-term-current-microamp = <128000>;
|
|
constant-charge-current-max-microamp = <900000>;
|
|
constant-charge-voltage-max-microvolt = <4200000>;
|
|
factory-internal-resistance-micro-ohms = <250000>;
|
|
ocv-capacity-celsius = <(-10) 0 10>;
|
|
/* table for -10 degree Celsius */
|
|
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
|
|
/* table for 0 degree Celsius */
|
|
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>;
|
|
/* table for 10 degree Celsius */
|
|
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>;
|
|
resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
|
|
operating-range-celsius = <(-30) 50>;
|
|
ambient-celsius = <(-5) 50>;
|
|
alert-celsius = <0 40>;
|
|
};
|
|
|
|
charger@11 {
|
|
reg = <0x11>;
|
|
monitored-battery = <&battery>;
|
|
};
|
|
|
|
fuel-gauge@22 {
|
|
reg = <0x22>;
|
|
monitored-battery = <&battery>;
|
|
};
|
|
};
|