Socionext Milbeaut UART controller
Required properties:
- compatible: should be "socionext,milbeaut-usio-uart".
- reg: offset and length of the register set for the device.
- interrupts: two interrupts specifier.
- interrupt-names: should be "rx", "tx".
- clocks: phandle to the input clock.
Optional properties:
- auto-flow-control: flow control enable.
Example:
usio1: usio_uart@1e700010 {
compatible = "socionext,milbeaut-usio-uart";
reg = <0x1e700010 0x10>;
interrupts = <0 141 0x4>, <0 149 0x4>;
interrupt-names = "rx", "tx";
clocks = <&clk 2>;
auto-flow-control;
};