39 lines
1.4 KiB
Plaintext
39 lines
1.4 KiB
Plaintext
What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_factory
|
|
Date: August 2021
|
|
KernelVersion: 5.16
|
|
Contact: Jacopo Mondi <jacopo@jmondi.org>
|
|
Description:
|
|
Writing '1' triggers a 'Factory' calibration cycle.
|
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_background
|
|
Date: August 2021
|
|
KernelVersion: 5.16
|
|
Contact: Jacopo Mondi <jacopo@jmondi.org>
|
|
Description:
|
|
Writing '1' triggers a 'Background' calibration cycle.
|
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/error_status_available
|
|
Date: August 2021
|
|
KernelVersion: 5.16
|
|
Contact: Jacopo Mondi <jacopo@jmondi.org>
|
|
Description:
|
|
Reading returns the list of possible chip error status.
|
|
Available options are:
|
|
- 'error_fatal': Analog front-end initialization error
|
|
- 'error_i2c': Read/write to non-existing register
|
|
- 'error_algorithm': Corrupted parameters
|
|
- 'error_calibration': Calibration has failed
|
|
- 'error_self_diagnostic': Internal interface failure
|
|
- 'error_out_of_range': Measured concentration out of scale
|
|
- 'error_memory': Error during memory operations
|
|
- 'error_no_measurement': Cleared at first measurement
|
|
- 'error_low_voltage': Sensor regulated voltage too low
|
|
- 'error_measurement_timeout': Unable to complete measurement
|
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/error_status
|
|
Date: August 2021
|
|
KernelVersion: 5.16
|
|
Contact: Jacopo Mondi <jacopo@jmondi.org>
|
|
Description:
|
|
Reading returns the current chip error status.
|