.. SPDX-License-Identifier: GFDL-1.1-no-invariants-or-later
.. _V4L2-TCH-FMT-DELTA-TD08:
********************************
V4L2_TCH_FMT_DELTA_TD08 ('TD08')
********************************
*man V4L2_TCH_FMT_DELTA_TD08(2)*
8-bit signed Touch Delta
Description
===========
This format represents delta data from a touch controller.
Delta values may range from -128 to 127. Typically the values will vary through
a small range depending on whether the sensor is touched or not. The full value
may be seen if one of the touchscreen nodes has a fault or the line is not
connected.
**Byte Order.**
Each cell is one byte.
.. flat-table::
:header-rows: 0
:stub-columns: 0
:widths: 2 1 1 1 1
* - start + 0:
- D'\ :sub:`00`
- D'\ :sub:`01`
- D'\ :sub:`02`
- D'\ :sub:`03`
* - start + 4:
- D'\ :sub:`10`
- D'\ :sub:`11`
- D'\ :sub:`12`
- D'\ :sub:`13`
* - start + 8:
- D'\ :sub:`20`
- D'\ :sub:`21`
- D'\ :sub:`22`
- D'\ :sub:`23`
* - start + 12:
- D'\ :sub:`30`
- D'\ :sub:`31`
- D'\ :sub:`32`
- D'\ :sub:`33`