# SPDX-License-Identifier: GPL-2.0
|
||
|
%YAML 1.2
|
||
|
---
|
||
|
$id: http://devicetree.org/schemas/timer/samsung,exynos4210-mct.yaml#
|
||
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||
|
|
||
|
title: Samsung Exynos SoC Multi Core Timer (MCT)
|
||
|
|
||
|
maintainers:
|
||
|
- Krzysztof Kozlowski <krzk@kernel.org>
|
||
|
|
||
|
description: |+
|
||
|
The Samsung's Multi Core Timer (MCT) module includes two main blocks, the
|
||
|
global timer and CPU local timers. The global timer is a 64-bit free running
|
||
|
up-counter and can generate 4 interrupts when the counter reaches one of the
|
||
|
four preset counter values. The CPU local timers are 32-bit free running
|
||
|
down-counters and generate an interrupt when the counter expires. There is
|
||
|
one CPU local timer instantiated in MCT for every CPU in the system.
|
||
|
|
||
|
properties:
|
||
|
compatible:
|
||
|
oneOf:
|
||
|
- enum:
|
||
|
- samsung,exynos4210-mct
|
||
|
- samsung,exynos4412-mct
|
||
|
- items:
|
||
|
- enum:
|
||
|
- axis,artpec8-mct
|
||
|
- samsung,exynos3250-mct
|
||
|
- samsung,exynos5250-mct
|
||
|
- samsung,exynos5260-mct
|
||
|
- samsung,exynos5420-mct
|
||
|
- samsung,exynos5433-mct
|
||
|
- samsung,exynos850-mct
|
||
|
- tesla,fsd-mct
|
||
|
- const: samsung,exynos4210-mct
|
||
|
|
||
|
clocks:
|
||
|
maxItems: 2
|
||
|
|
||
|
clock-names:
|
||
|
items:
|
||
|
- const: fin_pll
|
||
|
- const: mct
|
||
|
|
||
|
reg:
|
||
|
maxItems: 1
|
||
|
|
||
|
samsung,frc-shared:
|
||
|
type: boolean
|
||
|
description: |
|
||
|
Indicates that the hardware requires that this processor share the
|
||
|
free-running counter with a different (main) processor.
|
||
|
|
||
|
samsung,local-timers:
|
||
|
$ref: /schemas/types.yaml#/definitions/uint32-array
|
||
|
minItems: 1
|
||
|
maxItems: 16
|
||
|
description: |
|
||
|
List of indices of local timers usable from this processor.
|
||
|
|
||
|
interrupts:
|
||
|
description: |
|
||
|
Interrupts should be put in specific order. This is, the local timer
|
||
|
interrupts should be specified after the four global timer interrupts
|
||
|
have been specified:
|
||
|
0: Global Timer Interrupt 0
|
||
|
1: Global Timer Interrupt 1
|
||
|
2: Global Timer Interrupt 2
|
||
|
3: Global Timer Interrupt 3
|
||
|
4: Local Timer Interrupt 0
|
||
|
5: Local Timer Interrupt 1
|
||
|
6: ..
|
||
|
7: ..
|
||
|
i: Local Timer Interrupt n
|
||
|
For MCT block that uses a per-processor interrupt for local timers, such
|
||
|
as ones compatible with "samsung,exynos4412-mct", only one local timer
|
||
|
interrupt might be specified, meaning that all local timers use the same
|
||
|
per processor interrupt.
|
||
|
minItems: 5 # 4 Global + 1 local
|
||
|
maxItems: 20 # 4 Global + 16 local
|
||
|
|
||
|
required:
|
||
|
- compatible
|
||
|
- clock-names
|
||
|
- clocks
|
||
|
- interrupts
|
||
|
- reg
|
||
|
|
||
|
allOf:
|
||
|
- if:
|
||
|
not:
|
||
|
properties:
|
||
|
compatible:
|
||
|
contains:
|
||
|
enum:
|
||
|
- axis,artpec8-mct
|
||
|
then:
|
||
|
properties:
|
||
|
samsung,local-timers: false
|
||
|
samsung,frc-shared: false
|
||
|
- if:
|
||
|
properties:
|
||
|
compatible:
|
||
|
contains:
|
||
|
const: samsung,exynos3250-mct
|
||
|
then:
|
||
|
properties:
|
||
|
interrupts:
|
||
|
minItems: 8
|
||
|
maxItems: 8
|
||
|
|
||
|
- if:
|
||
|
properties:
|
||
|
compatible:
|
||
|
contains:
|
||
|
const: samsung,exynos5250-mct
|
||
|
then:
|
||
|
properties:
|
||
|
interrupts:
|
||
|
minItems: 6
|
||
|
maxItems: 6
|
||
|
|
||
|
- if:
|
||
|
properties:
|
||
|
compatible:
|
||
|
contains:
|
||
|
enum:
|
||
|
- axis,artpec8-mct
|
||
|
- samsung,exynos5260-mct
|
||
|
- samsung,exynos5420-mct
|
||
|
- samsung,exynos5433-mct
|
||
|
- samsung,exynos850-mct
|
||
|
then:
|
||
|
properties:
|
||
|
interrupts:
|
||
|
minItems: 12
|
||
|
maxItems: 12
|
||
|
|
||
|
- if:
|
||
|
properties:
|
||
|
compatible:
|
||
|
contains:
|
||
|
enum:
|
||
|
- tesla,fsd-mct
|
||
|
then:
|
||
|
properties:
|
||
|
interrupts:
|
||
|
minItems: 16
|
||
|
maxItems: 16
|
||
|
|
||
|
additionalProperties: false
|
||
|
|
||
|
examples:
|
||
|
- |
|
||
|
// In this example, the IP contains two local timers, using separate
|
||
|
// interrupts, so two local timer interrupts have been specified,
|
||
|
// in addition to four global timer interrupts.
|
||
|
#include <dt-bindings/clock/exynos4.h>
|
||
|
#include <dt-bindings/interrupt-controller/arm-gic.h>
|
||
|
|
||
|
timer@10050000 {
|
||
|
compatible = "samsung,exynos4210-mct";
|
||
|
reg = <0x10050000 0x800>;
|
||
|
clocks = <&clock CLK_FIN_PLL>, <&clock CLK_MCT>;
|
||
|
clock-names = "fin_pll", "mct";
|
||
|
|
||
|
interrupts = <GIC_SPI 57 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 69 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 70 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 71 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 42 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>;
|
||
|
};
|
||
|
|
||
|
- |
|
||
|
// In this example, the timer interrupts are connected to two separate
|
||
|
// interrupt controllers. Hence, an interrupts-extended is needed.
|
||
|
#include <dt-bindings/clock/exynos4.h>
|
||
|
#include <dt-bindings/interrupt-controller/arm-gic.h>
|
||
|
|
||
|
timer@101c0000 {
|
||
|
compatible = "samsung,exynos4210-mct";
|
||
|
reg = <0x101C0000 0x800>;
|
||
|
clocks = <&clock CLK_FIN_PLL>, <&clock CLK_MCT>;
|
||
|
clock-names = "fin_pll", "mct";
|
||
|
|
||
|
interrupts-extended = <&gic GIC_SPI 57 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<&gic GIC_SPI 69 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<&combiner 12 6>,
|
||
|
<&combiner 12 7>,
|
||
|
<&gic GIC_SPI 42 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<&gic GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>;
|
||
|
};
|
||
|
|
||
|
- |
|
||
|
// In this example, the IP contains four local timers, but using
|
||
|
// a per-processor interrupt to handle them. Only one first local
|
||
|
// interrupt is specified.
|
||
|
#include <dt-bindings/clock/exynos4.h>
|
||
|
#include <dt-bindings/interrupt-controller/arm-gic.h>
|
||
|
|
||
|
timer@10050000 {
|
||
|
compatible = "samsung,exynos4412-mct";
|
||
|
reg = <0x10050000 0x800>;
|
||
|
clocks = <&clock CLK_FIN_PLL>, <&clock CLK_MCT>;
|
||
|
clock-names = "fin_pll", "mct";
|
||
|
|
||
|
interrupts = <GIC_SPI 57 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 69 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 70 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 71 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_PPI 42 IRQ_TYPE_LEVEL_HIGH>;
|
||
|
};
|
||
|
|
||
|
- |
|
||
|
// In this example, the IP contains four local timers, but using
|
||
|
// a per-processor interrupt to handle them. All the local timer
|
||
|
// interrupts are specified.
|
||
|
#include <dt-bindings/clock/exynos4.h>
|
||
|
#include <dt-bindings/interrupt-controller/arm-gic.h>
|
||
|
|
||
|
timer@10050000 {
|
||
|
compatible = "samsung,exynos4412-mct";
|
||
|
reg = <0x10050000 0x800>;
|
||
|
clocks = <&clock CLK_FIN_PLL>, <&clock CLK_MCT>;
|
||
|
clock-names = "fin_pll", "mct";
|
||
|
|
||
|
interrupts = <GIC_SPI 57 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 69 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 70 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_SPI 71 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_PPI 42 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_PPI 42 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_PPI 42 IRQ_TYPE_LEVEL_HIGH>,
|
||
|
<GIC_PPI 42 IRQ_TYPE_LEVEL_HIGH>;
|
||
|
};
|