42 lines
1.3 KiB
ReStructuredText
42 lines
1.3 KiB
ReStructuredText
|
Kernel driver tmp108
|
||
|
====================
|
||
|
|
||
|
Supported chips:
|
||
|
|
||
|
* Texas Instruments TMP108
|
||
|
|
||
|
Prefix: 'tmp108'
|
||
|
|
||
|
Addresses scanned: none
|
||
|
|
||
|
Datasheet: https://www.ti.com/product/tmp108
|
||
|
|
||
|
Author:
|
||
|
|
||
|
John Muir <john@jmuir.com>
|
||
|
|
||
|
Description
|
||
|
-----------
|
||
|
|
||
|
The Texas Instruments TMP108 implements one temperature sensor. An alert pin
|
||
|
can be set when temperatures exceed minimum or maximum values plus or minus a
|
||
|
hysteresis value. (This driver does not support interrupts for the alert pin,
|
||
|
and the device runs in comparator mode.)
|
||
|
|
||
|
The sensor is accurate to 0.75C over the range of -25 to +85 C, and to 1.0
|
||
|
degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
|
||
|
operating temperature has a minimum of -55 C and a maximum of +150 C.
|
||
|
Hysteresis values can be set to 0, 1, 2, or 4C.
|
||
|
|
||
|
The TMP108 has a programmable update rate that can select between 8, 4, 1, and
|
||
|
0.5 Hz.
|
||
|
|
||
|
By default the TMP108 reads the temperature continuously. To conserve power,
|
||
|
the TMP108 has a one-shot mode where the device is normally shut-down. When a
|
||
|
one shot is requested the temperature is read, the result can be retrieved,
|
||
|
and then the device is shut down automatically. (This driver only supports
|
||
|
continuous mode.)
|
||
|
|
||
|
The driver provides the common sysfs-interface for temperatures (see
|
||
|
Documentation/hwmon/sysfs-interface.rst under Temperatures).
|