Marvell Armada AP80x System Controller
======================================
The AP806/AP807 is one of the two core HW blocks of the Marvell Armada
7K/8K/931x SoCs. It contains system controllers, which provide several
registers giving access to numerous features: clocks, pin-muxing and
many other SoC configuration items. This DT binding allows to describe
these system controllers.
For the top level node:
- compatible: must be: "syscon", "simple-mfd";
- reg: register area of the AP80x system controller
SYSTEM CONTROLLER 0
===================
Clocks:
-------
The Device Tree node representing the AP806/AP807 system controller
provides a number of clocks:
- 0: reference clock of CPU cluster 0
- 1: reference clock of CPU cluster 1
- 2: fixed PLL at 1200 Mhz
- 3: MSS clock, derived from the fixed PLL
Required properties:
- compatible: must be one of:
* "marvell,ap806-clock"
* "marvell,ap807-clock"
- #clock-cells: must be set to 1
Pinctrl:
--------
For common binding part and usage, refer to
Documentation/devicetree/bindings/pinctrl/marvell,mvebu-pinctrl.txt.
Required properties:
- compatible must be "marvell,ap806-pinctrl",
Available mpp pins/groups and functions:
Note: brackets (x) are not part of the mpp name for marvell,function and given
only for more detailed description in this document.
name pins functions
================================================================================
mpp0 0 gpio, sdio(clk), spi0(clk)
mpp1 1 gpio, sdio(cmd), spi0(miso)
mpp2 2 gpio, sdio(d0), spi0(mosi)
mpp3 3 gpio, sdio(d1), spi0(cs0n)
mpp4 4 gpio, sdio(d2), i2c0(sda)
mpp5 5 gpio, sdio(d3), i2c0(sdk)
mpp6 6 gpio, sdio(ds)
mpp7 7 gpio, sdio(d4), uart1(rxd)
mpp8 8 gpio, sdio(d5), uart1(txd)
mpp9 9 gpio, sdio(d6), spi0(cs1n)
mpp10 10 gpio, sdio(d7)
mpp11 11 gpio, uart0(txd)
mpp12 12 gpio, sdio(pw_off), sdio(hw_rst)
mpp13 13 gpio
mpp14 14 gpio
mpp15 15 gpio
mpp16 16 gpio
mpp17 17 gpio
mpp18 18 gpio
mpp19 19 gpio, uart0(rxd), sdio(pw_off)
GPIO:
-----
For common binding part and usage, refer to
Documentation/devicetree/bindings/gpio/gpio-mvebu.yaml.
Required properties:
- compatible: "marvell,armada-8k-gpio"
- offset: offset address inside the syscon block
Optional properties:
- marvell,pwm-offset: offset address of PWM duration control registers inside
the syscon block
Example:
ap_syscon: system-controller@6f4000 {
compatible = "syscon", "simple-mfd";
reg = <0x6f4000 0x1000>;
ap_clk: clock {
compatible = "marvell,ap806-clock";
#clock-cells = <1>;
};
ap_pinctrl: pinctrl {
compatible = "marvell,ap806-pinctrl";
};
ap_gpio: gpio {
compatible = "marvell,armada-8k-gpio";
offset = <0x1040>;
ngpios = <19>;
gpio-controller;
#gpio-cells = <2>;
gpio-ranges = <&ap_pinctrl 0 0 19>;
marvell,pwm-offset = <0x10c0>;
#pwm-cells = <2>;
clocks = <&ap_clk 3>;
};
};
SYSTEM CONTROLLER 1
===================
Thermal:
--------
For common binding part and usage, refer to
Documentation/devicetree/bindings/thermal/thermal*.yaml
The thermal IP can probe the temperature all around the processor. It
may feature several channels, each of them wired to one sensor.
It is possible to setup an overheat interrupt by giving at least one
critical point to any subnode of the thermal-zone node.
Required properties:
- compatible: must be one of:
* marvell,armada-ap806-thermal
- reg: register range associated with the thermal functions.
Optional properties:
- interrupts: overheat interrupt handle. Should point to line 18 of the
SEI irqchip. See interrupt-controller/interrupts.txt
- #thermal-sensor-cells: shall be <1> when thermal-zones subnodes refer
to this IP and represents the channel ID. There is one sensor per
channel. O refers to the thermal IP internal channel, while positive
IDs refer to each CPU.
Example:
ap_syscon1: system-controller@6f8000 {
compatible = "syscon", "simple-mfd";
reg = <0x6f8000 0x1000>;
ap_thermal: thermal-sensor@80 {
compatible = "marvell,armada-ap806-thermal";
reg = <0x80 0x10>;
interrupt-parent = <&sei>;
interrupts = <18>;
#thermal-sensor-cells = <1>;
};
};
Cluster clocks:
---------------
Device Tree Clock bindings for cluster clock of Marvell
AP806/AP807. Each cluster contain up to 2 CPUs running at the same
frequency.
Required properties:
- compatible: must be one of:
* "marvell,ap806-cpu-clock"
* "marvell,ap807-cpu-clock"
- #clock-cells : should be set to 1.
- clocks : shall be the input parent clock(s) phandle for the clock
(one per cluster)
- reg: register range associated with the cluster clocks
ap_syscon1: system-controller@6f8000 {
compatible = "marvell,armada-ap806-syscon1", "syscon", "simple-mfd";
reg = <0x6f8000 0x1000>;
cpu_clk: clock-cpu@278 {
compatible = "marvell,ap806-cpu-clock";
clocks = <&ap_clk 0>, <&ap_clk 1>;
#clock-cells = <1>;
reg = <0x278 0xa30>;
};
};