.. SPDX-License-Identifier: (GPL-2.0-only OR BSD-3-Clause)
|
||
|
|
||
|
can327: ELM327 driver for Linux SocketCAN
|
||
|
==========================================
|
||
|
|
||
|
Authors
|
||
|
--------
|
||
|
|
||
|
Max Staudt <max@enpas.org>
|
||
|
|
||
|
|
||
|
|
||
|
Motivation
|
||
|
-----------
|
||
|
|
||
|
This driver aims to lower the initial cost for hackers interested in
|
||
|
working with CAN buses.
|
||
|
|
||
|
CAN adapters are expensive, few, and far between.
|
||
|
ELM327 interfaces are cheap and plentiful.
|
||
|
Let's use ELM327s as CAN adapters.
|
||
|
|
||
|
|
||
|
|
||
|
Introduction
|
||
|
-------------
|
||
|
|
||
|
This driver is an effort to turn abundant ELM327 based OBD interfaces
|
||
|
into full fledged (as far as possible) CAN interfaces.
|
||
|
|
||
|
Since the ELM327 was never meant to be a stand alone CAN controller,
|
||
|
the driver has to switch between its modes as quickly as possible in
|
||
|
order to fake full-duplex operation.
|
||
|
|
||
|
As such, can327 is a best effort driver. However, this is more than
|
||
|
enough to implement simple request-response protocols (such as OBD II),
|
||
|
and to monitor broadcast messages on a bus (such as in a vehicle).
|
||
|
|
||
|
Most ELM327s come as nondescript serial devices, attached via USB or
|
||
|
Bluetooth. The driver cannot recognize them by itself, and as such it
|
||
|
is up to the user to attach it in form of a TTY line discipline
|
||
|
(similar to PPP, SLIP, slcan, ...).
|
||
|
|
||
|
This driver is meant for ELM327 versions 1.4b and up, see below for
|
||
|
known limitations in older controllers and clones.
|
||
|
|
||
|
|
||
|
|
||
|
Data sheet
|
||
|
-----------
|
||
|
|
||
|
The official data sheets can be found at ELM electronics' home page:
|
||
|
|
||
|
https://www.elmelectronics.com/
|
||
|
|
||
|
|
||
|
|
||
|
How to attach the line discipline
|
||
|
----------------------------------
|
||
|
|
||
|
Every ELM327 chip is factory programmed to operate at a serial setting
|
||
|
of 38400 baud/s, 8 data bits, no parity, 1 stopbit.
|
||
|
|
||
|
If you have kept this default configuration, the line discipline can
|
||
|
be attached on a command prompt as follows::
|
||
|
|
||
|
sudo ldattach \
|
||
|
--debug \
|
||
|
--speed 38400 \
|
||
|
--eightbits \
|
||
|
--noparity \
|
||
|
--onestopbit \
|
||
|
--iflag -ICRNL,INLCR,-IXOFF \
|
||
|
30 \
|
||
|
/dev/ttyUSB0
|
||
|
|
||
|
To change the ELM327's serial settings, please refer to its data
|
||
|
sheet. This needs to be done before attaching the line discipline.
|
||
|
|
||
|
Once the ldisc is attached, the CAN interface starts out unconfigured.
|
||
|
Set the speed before starting it::
|
||
|
|
||
|
# The interface needs to be down to change parameters
|
||
|
sudo ip link set can0 down
|
||
|
sudo ip link set can0 type can bitrate 500000
|
||
|
sudo ip link set can0 up
|
||
|
|
||
|
500000 bit/s is a common rate for OBD-II diagnostics.
|
||
|
If you're connecting straight to a car's OBD port, this is the speed
|
||
|
that most cars (but not all!) expect.
|
||
|
|
||
|
After this, you can set out as usual with candump, cansniffer, etc.
|
||
|
|
||
|
|
||
|
|
||
|
How to check the controller version
|
||
|
------------------------------------
|
||
|
|
||
|
Use a terminal program to attach to the controller.
|
||
|
|
||
|
After issuing the "``AT WS``" command, the controller will respond with
|
||
|
its version::
|
||
|
|
||
|
>AT WS
|
||
|
|
||
|
|
||
|
ELM327 v1.4b
|
||
|
|
||
|
>
|
||
|
|
||
|
Note that clones may claim to be any version they like.
|
||
|
It is not indicative of their actual feature set.
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
Communication example
|
||
|
----------------------
|
||
|
|
||
|
This is a short and incomplete introduction on how to talk to an ELM327.
|
||
|
It is here to guide understanding of the controller's and the driver's
|
||
|
limitation (listed below) as well as manual testing.
|
||
|
|
||
|
|
||
|
The ELM327 has two modes:
|
||
|
|
||
|
- Command mode
|
||
|
- Reception mode
|
||
|
|
||
|
In command mode, it expects one command per line, terminated by CR.
|
||
|
By default, the prompt is a "``>``", after which a command can be
|
||
|
entered::
|
||
|
|
||
|
>ATE1
|
||
|
OK
|
||
|
>
|
||
|
|
||
|
The init script in the driver switches off several configuration options
|
||
|
that are only meaningful in the original OBD scenario the chip is meant
|
||
|
for, and are actually a hindrance for can327.
|
||
|
|
||
|
|
||
|
When a command is not recognized, such as by an older version of the
|
||
|
ELM327, a question mark is printed as a response instead of OK::
|
||
|
|
||
|
>ATUNKNOWN
|
||
|
?
|
||
|
>
|
||
|
|
||
|
At present, can327 does not evaluate this response. See the section
|
||
|
below on known limitations for details.
|
||
|
|
||
|
|
||
|
When a CAN frame is to be sent, the target address is configured, after
|
||
|
which the frame is sent as a command that consists of the data's hex
|
||
|
dump::
|
||
|
|
||
|
>ATSH123
|
||
|
OK
|
||
|
>DEADBEEF12345678
|
||
|
OK
|
||
|
>
|
||
|
|
||
|
The above interaction sends the SFF frame "``DE AD BE EF 12 34 56 78``"
|
||
|
with (11 bit) CAN ID ``0x123``.
|
||
|
For this to function, the controller must be configured for SFF sending
|
||
|
mode (using "``AT PB``", see code or datasheet).
|
||
|
|
||
|
|
||
|
Once a frame has been sent and wait-for-reply mode is on (``ATR1``,
|
||
|
configured on ``listen-only=off``), or when the reply timeout expires
|
||
|
and the driver sets the controller into monitoring mode (``ATMA``),
|
||
|
the ELM327 will send one line for each received CAN frame, consisting
|
||
|
of CAN ID, DLC, and data::
|
||
|
|
||
|
123 8 DEADBEEF12345678
|
||
|
|
||
|
For EFF (29 bit) CAN frames, the address format is slightly different,
|
||
|
which can327 uses to tell the two apart::
|
||
|
|
||
|
12 34 56 78 8 DEADBEEF12345678
|
||
|
|
||
|
The ELM327 will receive both SFF and EFF frames - the current CAN
|
||
|
config (``ATPB``) does not matter.
|
||
|
|
||
|
|
||
|
If the ELM327's internal UART sending buffer runs full, it will abort
|
||
|
the monitoring mode, print "BUFFER FULL" and drop back into command
|
||
|
mode. Note that in this case, unlike with other error messages, the
|
||
|
error message may appear on the same line as the last (usually
|
||
|
incomplete) data frame::
|
||
|
|
||
|
12 34 56 78 8 DEADBEEF123 BUFFER FULL
|
||
|
|
||
|
|
||
|
|
||
|
Known limitations of the controller
|
||
|
------------------------------------
|
||
|
|
||
|
- Clone devices ("v1.5" and others)
|
||
|
|
||
|
Sending RTR frames is not supported and will be dropped silently.
|
||
|
|
||
|
Receiving RTR with DLC 8 will appear to be a regular frame with
|
||
|
the last received frame's DLC and payload.
|
||
|
|
||
|
"``AT CSM``" (CAN Silent Monitoring, i.e. don't send CAN ACKs) is
|
||
|
not supported, and is hard coded to ON. Thus, frames are not ACKed
|
||
|
while listening: "``AT MA``" (Monitor All) will always be "silent".
|
||
|
However, immediately after sending a frame, the ELM327 will be in
|
||
|
"receive reply" mode, in which it *does* ACK any received frames.
|
||
|
Once the bus goes silent, or an error occurs (such as BUFFER FULL),
|
||
|
or the receive reply timeout runs out, the ELM327 will end reply
|
||
|
reception mode on its own and can327 will fall back to "``AT MA``"
|
||
|
in order to keep monitoring the bus.
|
||
|
|
||
|
Other limitations may apply, depending on the clone and the quality
|
||
|
of its firmware.
|
||
|
|
||
|
|
||
|
- All versions
|
||
|
|
||
|
No full duplex operation is supported. The driver will switch
|
||
|
between input/output mode as quickly as possible.
|
||
|
|
||
|
The length of outgoing RTR frames cannot be set. In fact, some
|
||
|
clones (tested with one identifying as "``v1.5``") are unable to
|
||
|
send RTR frames at all.
|
||
|
|
||
|
We don't have a way to get real-time notifications on CAN errors.
|
||
|
While there is a command (``AT CS``) to retrieve some basic stats,
|
||
|
we don't poll it as it would force us to interrupt reception mode.
|
||
|
|
||
|
|
||
|
- Versions prior to 1.4b
|
||
|
|
||
|
These versions do not send CAN ACKs when in monitoring mode (AT MA).
|
||
|
However, they do send ACKs while waiting for a reply immediately
|
||
|
after sending a frame. The driver maximizes this time to make the
|
||
|
controller as useful as possible.
|
||
|
|
||
|
Starting with version 1.4b, the ELM327 supports the "``AT CSM``"
|
||
|
command, and the "listen-only" CAN option will take effect.
|
||
|
|
||
|
|
||
|
- Versions prior to 1.4
|
||
|
|
||
|
These chips do not support the "``AT PB``" command, and thus cannot
|
||
|
change bitrate or SFF/EFF mode on-the-fly. This will have to be
|
||
|
programmed by the user before attaching the line discipline. See the
|
||
|
data sheet for details.
|
||
|
|
||
|
|
||
|
- Versions prior to 1.3
|
||
|
|
||
|
These chips cannot be used at all with can327. They do not support
|
||
|
the "``AT D1``" command, which is necessary to avoid parsing conflicts
|
||
|
on incoming data, as well as distinction of RTR frame lengths.
|
||
|
|
||
|
Specifically, this allows for easy distinction of SFF and EFF
|
||
|
frames, and to check whether frames are complete. While it is possible
|
||
|
to deduce the type and length from the length of the line the ELM327
|
||
|
sends us, this method fails when the ELM327's UART output buffer
|
||
|
overruns. It may abort sending in the middle of the line, which will
|
||
|
then be mistaken for something else.
|
||
|
|
||
|
|
||
|
|
||
|
Known limitations of the driver
|
||
|
--------------------------------
|
||
|
|
||
|
- No 8/7 timing.
|
||
|
|
||
|
ELM327 can only set CAN bitrates that are of the form 500000/n, where
|
||
|
n is an integer divisor.
|
||
|
However there is an exception: With a separate flag, it may set the
|
||
|
speed to be 8/7 of the speed indicated by the divisor.
|
||
|
This mode is not currently implemented.
|
||
|
|
||
|
- No evaluation of command responses.
|
||
|
|
||
|
The ELM327 will reply with OK when a command is understood, and with ?
|
||
|
when it is not. The driver does not currently check this, and simply
|
||
|
assumes that the chip understands every command.
|
||
|
The driver is built such that functionality degrades gracefully
|
||
|
nevertheless. See the section on known limitations of the controller.
|
||
|
|
||
|
- No use of hardware CAN ID filtering
|
||
|
|
||
|
An ELM327's UART sending buffer will easily overflow on heavy CAN bus
|
||
|
load, resulting in the "``BUFFER FULL``" message. Using the hardware
|
||
|
filters available through "``AT CF xxx``" and "``AT CM xxx``" would be
|
||
|
helpful here, however SocketCAN does not currently provide a facility
|
||
|
to make use of such hardware features.
|
||
|
|
||
|
|
||
|
|
||
|
Rationale behind the chosen configuration
|
||
|
------------------------------------------
|
||
|
|
||
|
``AT E1``
|
||
|
Echo on
|
||
|
|
||
|
We need this to be able to get a prompt reliably.
|
||
|
|
||
|
``AT S1``
|
||
|
Spaces on
|
||
|
|
||
|
We need this to distinguish 11/29 bit CAN addresses received.
|
||
|
|
||
|
Note:
|
||
|
We can usually do this using the line length (odd/even),
|
||
|
but this fails if the line is not transmitted fully to
|
||
|
the host (BUFFER FULL).
|
||
|
|
||
|
``AT D1``
|
||
|
DLC on
|
||
|
|
||
|
We need this to tell the "length" of RTR frames.
|
||
|
|
||
|
|
||
|
|
||
|
A note on CAN bus termination
|
||
|
------------------------------
|
||
|
|
||
|
Your adapter may have resistors soldered in which are meant to terminate
|
||
|
the bus. This is correct when it is plugged into a OBD-II socket, but
|
||
|
not helpful when trying to tap into the middle of an existing CAN bus.
|
||
|
|
||
|
If communications don't work with the adapter connected, check for the
|
||
|