# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
|
||
|
%YAML 1.2
|
||
|
---
|
||
|
$id: http://devicetree.org/schemas/display/panel/panel-edp.yaml#
|
||
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||
|
|
||
|
title: Probeable (via DP AUX / EDID) eDP Panels with simple poweron sequences
|
||
|
|
||
|
maintainers:
|
||
|
- Douglas Anderson <dianders@chromium.org>
|
||
|
|
||
|
description: |
|
||
|
This binding file can be used to indicate that an eDP panel is connected
|
||
|
to a Embedded DisplayPort AUX bus (see display/dp-aux-bus.yaml) without
|
||
|
actually specifying exactly what panel is connected. This is useful for
|
||
|
the case that more than one different panel could be connected to the
|
||
|
board, either for second-sourcing purposes or to support multiple SKUs
|
||
|
with different LCDs that hook up to a common board.
|
||
|
|
||
|
As per above, a requirement for using this binding is that the panel is
|
||
|
represented under the DP AUX bus. This means that we can use any
|
||
|
information provided by the DP AUX bus (including the EDID) to identify
|
||
|
the panel. We can use this to identify display size, resolution, and
|
||
|
timings among other things.
|
||
|
|
||
|
One piece of information about eDP panels that is typically _not_
|
||
|
provided anywhere on the DP AUX bus is the power sequencing timings.
|
||
|
This is the reason why, historically, we've always had to explicitly
|
||
|
list eDP panels. We solve that here with two tricks. The "worst case"
|
||
|
power on timings for any panels expected to be connected to a board are
|
||
|
specified in these bindings. Once we've powered on, it's expected that
|
||
|
the operating system will lookup the panel in a table (based on EDID
|
||
|
information) to figure out other power sequencing timings.
|
||
|
|
||
|
eDP panels in general can have somewhat arbitrary power sequencing
|
||
|
requirements. However, even though it's arbitrary in general, the
|
||
|
vast majority of panel datasheets have a power sequence diagram that
|
||
|
looks the exactly the same as every other panel. Each panel datasheet
|
||
|
cares about different timings in this diagram but the fact that the
|
||
|
diagram is so similar means we can come up with a single driver to
|
||
|
handle it.
|
||
|
|
||
|
These diagrams all look roughly like this, sometimes labeled with
|
||
|
slightly different numbers / lines but all pretty much the same
|
||
|
sequence. This is because much of this diagram comes straight from
|
||
|
the eDP Standard.
|
||
|
|
||
|
__________________________________________________
|
||
|
Vdd ___/: :\____ /
|
||
|
_/ : : \_____/
|
||
|
:<T1>:<T2>: :<--T10-->:<T11>:<T12>:
|
||
|
: +-----------------------+---------+---------+
|
||
|
eDP -----------+ Black video | Src vid | Blk vid +
|
||
|
Display : +-----------------------+---------+---------+
|
||
|
: _______________________:_________:_________:
|
||
|
HPD :<T3>| : : |
|
||
|
___________| : : |_____________
|
||
|
: : : :
|
||
|
Sink +-----------------------:---------:---------+
|
||
|
AUX CH -----------+ AUX Ch operational : : +-------------
|
||
|
+-----------------------:---------:---------+
|
||
|
: : : :
|
||
|
:<T4>: :<T7>: : :
|
||
|
Src main +------+------+--------------+---------+
|
||
|
lnk data----------------+LnkTrn| Idle |Valid vid data| Idle/off+-------------
|
||
|
+------+------+--------------+---------+
|
||
|
: <T5> :<-T6->:<-T8->: :
|
||
|
:__:<T9>:
|
||
|
LED_EN | |
|
||
|
_____________________________________| |____________________________
|
||
|
: :
|
||
|
__________:__:_
|
||
|
PWM | : : |
|
||
|
__________________________| : : |__________________________
|
||
|
: : : :
|
||
|
_____________:__________:__:_:______
|
||
|
Bklight ____/: : : : : :\____
|
||
|
power _______/ :<---T13---->: : : :<T16>: \______________
|
||
|
(Vbl) :<T17>:<---------T14--------->: :<-T15->:<T18>:
|
||
|
|
||
|
The above looks fairly complex but, as per above, each panel only cares
|
||
|
about a subset of those timings.
|
||
|
|
||
|
allOf:
|
||
|
- $ref: panel-common.yaml#
|
||
|
|
||
|
properties:
|
||
|
compatible:
|
||
|
const: edp-panel
|
||
|
|
||
|
hpd-reliable-delay-ms:
|
||
|
description:
|
||
|
A fixed amount of time that must be waited after powering on the
|
||
|
panel's power-supply before the HPD signal is a reliable way to know
|
||
|
when the AUX channel is ready. This is useful for panels that glitch
|
||
|
the HPD at the start of power-on. This value is not needed if HPD is
|
||
|
always reliable for all panels that might be connected.
|
||
|
|
||
|
hpd-absent-delay-ms:
|
||
|
description:
|
||
|
The panel specifies that HPD will be asserted this many milliseconds
|
||
|
from power on (timing T3 in the diagram above). If we have no way to
|
||
|
measure HPD then a fixed delay of this many milliseconds can be used.
|
||
|
This can also be used as a timeout when waiting for HPD. Does not
|
||
|
include the hpd-reliable-delay, so if hpd-reliable-delay was 80 ms
|
||
|
and hpd-absent-delay was 200 ms then we'd do a fixed 80 ms delay and
|
||
|
then we know HPD would assert in the next 120 ms. This value is not
|
||
|
needed if HPD hooked up, either through a GPIO in the panel node or
|
||
|
hooked up directly to the eDP controller.
|
||
|
|
||
|
backlight: true
|
||
|
enable-gpios: true
|
||
|
port: true
|
||
|
power-supply: true
|
||
|
no-hpd: true
|
||
|
hpd-gpios: true
|
||
|
|
||
|
additionalProperties: false
|
||
|
|
||
|
required:
|
||
|
- compatible
|
||
|
- power-supply
|
||
|
|
||
|
examples:
|
||
|
- |
|
||
|
#include <dt-bindings/clock/qcom,rpmh.h>
|
||
|
#include <dt-bindings/gpio/gpio.h>
|
||
|
#include <dt-bindings/interrupt-controller/irq.h>
|
||
|
|
||
|
i2c {
|
||
|
#address-cells = <1>;
|
||
|
#size-cells = <0>;
|
||
|
|
||
|
bridge@2d {
|
||
|
compatible = "ti,sn65dsi86";
|
||
|
reg = <0x2d>;
|
||
|
|
||
|
interrupt-parent = <&tlmm>;
|
||
|
interrupts = <10 IRQ_TYPE_LEVEL_HIGH>;
|
||
|
|
||
|
enable-gpios = <&tlmm 102 GPIO_ACTIVE_HIGH>;
|
||
|
|
||
|
vpll-supply = <&src_pp1800_s4a>;
|
||
|
vccio-supply = <&src_pp1800_s4a>;
|
||
|
vcca-supply = <&src_pp1200_l2a>;
|
||
|
vcc-supply = <&src_pp1200_l2a>;
|
||
|
|
||
|
clocks = <&rpmhcc RPMH_LN_BB_CLK2>;
|
||
|
clock-names = "refclk";
|
||
|
|
||
|
no-hpd;
|
||
|
|
||
|
ports {
|
||
|
#address-cells = <1>;
|
||
|
#size-cells = <0>;
|
||
|
|
||
|
port@0 {
|
||
|
reg = <0>;
|
||
|
endpoint {
|
||
|
remote-endpoint = <&dsi0_out>;
|
||
|
};
|
||
|
};
|
||
|
|
||
|
port@1 {
|
||
|
reg = <1>;
|
||
|
sn65dsi86_out: endpoint {
|
||
|
remote-endpoint = <&panel_in_edp>;
|
||
|
};
|
||
|
};
|
||
|
};
|
||
|
|
||
|
aux-bus {
|
||
|
panel {
|
||
|
compatible = "edp-panel";
|
||
|
power-supply = <&pp3300_dx_edp>;
|
||
|
backlight = <&backlight>;
|
||
|
hpd-gpios = <&sn65dsi86_bridge 2 GPIO_ACTIVE_HIGH>;
|
||
|
hpd-reliable-delay-ms = <15>;
|
||
|
|
||
|
port {
|
||
|
panel_in_edp: endpoint {
|
||
|
remote-endpoint = <&sn65dsi86_out>;
|
||
|
};
|
||
|
};
|
||
|
};
|
||
|
};
|
||
|
};
|
||
|
};
|