Pierre Morel a54b8ac340 css: SCHIB measurement block origin must be aligned
The Measurement Block Origin inside the SCHIB is used when
Measurement Block format 1 is in used and must be aligned
on 64 bytes otherwise an operand exception is recognized
when issuing the Modify Sub CHannel (MSCH) instruction.

Signed-off-by: Pierre Morel <pmorel@linux.ibm.com>
Reviewed-by: Thomas Huth <thuth@redhat.com>
Message-Id: <1613741973-3711-2-git-send-email-pmorel@linux.ibm.com>
Signed-off-by: Cornelia Huck <cohuck@redhat.com>
2021-03-04 11:23:35 +01:00
..
2021-02-18 08:25:06 -08:00
2021-02-18 08:25:06 -08:00