Document the usage modes, host primary graphics considerations, usage, and fw_cfg ABI required for IGD assignment with vfio. Signed-off-by: Alex Williamson <alex.williamson@redhat.com> Reviewed-by: Gerd Hoffmann <kraxel@redhat.com> Tested-by: Gerd Hoffmann <kraxel@redhat.com>
		
			
				
	
	
		
			134 lines
		
	
	
		
			7.1 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			134 lines
		
	
	
		
			7.1 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
Intel Graphics Device (IGD) assignment with vfio-pci
 | 
						|
====================================================
 | 
						|
 | 
						|
IGD has two different modes for assignment using vfio-pci:
 | 
						|
 | 
						|
1) Universal Pass-Through (UPT) mode:
 | 
						|
 | 
						|
   In this mode the IGD device is added as a *secondary* (ie. non-primary)
 | 
						|
   graphics device in combination with an emulated primary graphics device.
 | 
						|
   This mode *requires* guest driver support to remove the external
 | 
						|
   dependencies generally associated with IGD (see below).  Those guest
 | 
						|
   drivers only support this mode for Broadwell and newer IGD, according to
 | 
						|
   Intel.  Additionally, this mode by default, and as officially supported
 | 
						|
   by Intel, does not support direct video output.  The intention is to use
 | 
						|
   this mode either to provide hardware acceleration to the emulated graphics
 | 
						|
   or to use this mode in combination with guest-based remote access software,
 | 
						|
   for example VNC (see below for optional output support).  This mode
 | 
						|
   theoretically has no device specific handling dependencies on vfio-pci or
 | 
						|
   the VM firmware.
 | 
						|
 | 
						|
2) "Legacy" mode:
 | 
						|
 | 
						|
   In this mode the IGD device is intended to be the primary and exclusive
 | 
						|
   graphics device in the VM[1], as such QEMU does not facilitate any sort
 | 
						|
   of remote graphics to the VM in this mode.  A connected physical monitor
 | 
						|
   is the intended output device for IGD.  This mode includes several
 | 
						|
   requirements and restrictions:
 | 
						|
 | 
						|
    * IGD must be given address 02.0 on the PCI root bus in the VM
 | 
						|
    * The host kernel must support vfio extensions for IGD (v4.6)
 | 
						|
    * vfio VGA support very likely needs to be enabled in the host kernel
 | 
						|
    * The VM firmware must support specific fw_cfg enablers for IGD
 | 
						|
    * The VM machine type must support a PCI host bridge at 00.0 (standard)
 | 
						|
    * The VM machine type must provide or allow to be created a special
 | 
						|
      ISA/LPC bridge device (vfio-pci-igd-lpc-bridge) on the root bus at
 | 
						|
      PCI address 1f.0.
 | 
						|
    * The IGD device must have a VGA ROM, either provided via the romfile
 | 
						|
      option or loaded automatically through vfio (standard).  rombar=0
 | 
						|
      will disable legacy mode support.
 | 
						|
    * Hotplug of the IGD device is not supported.
 | 
						|
    * The IGD device must be a SandyBridge or newer model device.
 | 
						|
 | 
						|
For either mode, depending on the host kernel, the i915 driver in the host
 | 
						|
may generate faults and errors upon re-binding to an IGD device after it
 | 
						|
has been assigned to a VM.  It's therefore generally recommended to prevent
 | 
						|
such driver binding unless the host driver is known to work well for this.
 | 
						|
There are numerous ways to do this, i915 can be blacklisted on the host,
 | 
						|
the driver_override option can be used to ensure that only vfio-pci can bind
 | 
						|
to the device on the host[2], virsh nodedev-detach can be used to bind the
 | 
						|
device to vfio drivers and then managed='no' set in the VM xml to prevent
 | 
						|
re-binding to i915, etc.  Also note that IGD is also typically the primary
 | 
						|
graphics in the host and special options may be required beyond simply
 | 
						|
blacklisting i915 or using pci-stub/vfio-pci to take ownership of IGD as a
 | 
						|
PCI class device.  Lower level drivers exist that may still claim the device.
 | 
						|
It may therefore be necessary to use kernel boot options video=vesafb:off or
 | 
						|
video=efifb:off (depending on host BIOS/UEFI) or these can be combined to
 | 
						|
a catch-all, video=vesafb:off,efifb:off.  Error messages such as:
 | 
						|
 | 
						|
    Failed to mmap 0000:00:02.0 BAR <>. Performance may be slow
 | 
						|
 | 
						|
are a good indicator that such a problem exists.  The host files /proc/iomem
 | 
						|
and /proc/ioports are often useful for identifying drivers consuming ranges
 | 
						|
of the device to cause such conflicts.
 | 
						|
 | 
						|
Additionally, IGD device are known to generate small numbers of DMAR faults
 | 
						|
when initially assigned.  It is believed that this is simply the IGD attempting
 | 
						|
to access the reserved GTT space after reset, which it no longer has access to
 | 
						|
when accessed from userspace.  So long as the DMAR faults are small in number
 | 
						|
and most importantly, not ongoing, these are not an indication of an error.
 | 
						|
 | 
						|
Additionally++, analog VGA output (as opposed to digital outputs like HDMI,
 | 
						|
DVI, or DisplayPort) may be unsupported in some use cases.  In the author's
 | 
						|
experience, even DP to VGA adapters can be troublesome while adapters between
 | 
						|
digital formats work well.
 | 
						|
 | 
						|
Usage
 | 
						|
=====
 | 
						|
The intention is for IGD assignment to be transparent for users and thus for
 | 
						|
management tools like libvirt.  To make use of legacy mode, simply remove all
 | 
						|
other graphics options and use "-nographic" and either "-vga none" or
 | 
						|
"-nodefaults", along with adding the device using vfio-pci:
 | 
						|
 | 
						|
    -device vfio-pci,host=00:02.0,id=hostdev0,bus=pci.0,addr=0x2
 | 
						|
 | 
						|
For UPT mode, retain the default emulated graphics and simply add the vfio-pci
 | 
						|
device making use of any other bus address other than 02.0.  libvirt will
 | 
						|
default to assigning the device a UPT compatible address while legacy mode
 | 
						|
users will need to manually edit the XML if using a tool like virt-manager
 | 
						|
where the VM device address is not expressly specified.
 | 
						|
 | 
						|
An experimental vfio-pci option also exists to enable OpRegion, and thus
 | 
						|
external monitor support, for UPT mode.  This can be enabled by adding
 | 
						|
"x-igd-opregion=on" to the vfio-pci device options for the IGD device.  As
 | 
						|
with legacy mode, this requires the host to support features introduced in
 | 
						|
the v4.6 kernel.  If Intel chooses to embrace this support, the option may
 | 
						|
be made non-experimental in the future, opening it to libvirt support.
 | 
						|
 | 
						|
Developer ABI
 | 
						|
=============
 | 
						|
Legacy mode IGD support imposes two fw_cfg requirements on the VM firmware:
 | 
						|
 | 
						|
1) "etc/igd-opregion"
 | 
						|
 | 
						|
   This fw_cfg file exposes the OpRegion for the IGD device.  A reserved
 | 
						|
   region should be created below 4GB (recommended 4KB alignment), sized
 | 
						|
   sufficient for the fw_cfg file size, and the content of this file copied
 | 
						|
   to it.  The dword based address of this reserved memory region must also
 | 
						|
   be written to the ASLS register at offset 0xFC on the IGD device.  It is
 | 
						|
   recommended that firmware should make use of this fw_cfg entry for any
 | 
						|
   PCI class VGA device with Intel vendor ID.  Multiple of such devices
 | 
						|
   within a VM is undefined.
 | 
						|
 | 
						|
2) "etc/igd-bdsm-size"
 | 
						|
 | 
						|
   This fw_cfg file contains an 8-byte, little endian integer indicating
 | 
						|
   the size of the reserved memory region required for IGD stolen memory.
 | 
						|
   Firmware must allocate a reserved memory below 4GB with required 1MB
 | 
						|
   alignment equal to this size.  Additionally the base address of this
 | 
						|
   reserved region must be written to the dword BDSM register in PCI config
 | 
						|
   space of the IGD device at offset 0x5C.  As this support is related to
 | 
						|
   running the IGD ROM, which has other dependencies on the device appearing
 | 
						|
   at guest address 00:02.0, it's expected that this fw_cfg file is only
 | 
						|
   relevant to a single PCI class VGA device with Intel vendor ID, appearing
 | 
						|
   at PCI bus address 00:02.0.
 | 
						|
 | 
						|
Footnotes
 | 
						|
=========
 | 
						|
[1] Nothing precludes adding additional emulated or assigned graphics devices
 | 
						|
    as non-primary, other than the combination typically not working.  I only
 | 
						|
    intend to set user expectations, others are welcome to find working
 | 
						|
    combinations or fix whatever issues prevent this from working in the common
 | 
						|
    case.
 | 
						|
[2] # echo "vfio-pci" > /sys/bus/pci/devices/0000:00:02.0/driver_override
 |