Cédric Le Goater 3fe4f0fc85 spapr/rtas: do not reset the MSR in stop-self command
When a CPU is stopped with the 'stop-self' RTAS call, its state
'halted' is switched to 1 and, in this case, the MSR is not taken into
account anymore in the cpu_has_work() routine. Only the pending
hardware interrupts are checked with their LPCR:PECE* enablement bit.

The CPU is now also protected from the decrementer interrupt by the
LPCR:PECE* bits which are disabled in the 'stop-self' RTAS
call. Reseting the MSR is pointless.

Signed-off-by: Cédric Le Goater <clg@kaod.org>
Reviewed-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
2017-12-15 09:49:24 +11:00
..
2017-12-15 09:49:23 +11:00
2017-09-08 09:30:55 +10:00
2017-04-26 12:41:55 +10:00
2017-01-19 22:07:46 +01:00
2017-09-08 09:30:55 +10:00
2017-05-07 09:57:51 +03:00
2017-01-31 10:10:13 +11:00
2017-01-31 10:10:13 +11:00
2017-11-20 10:10:56 +11:00
2017-09-27 11:35:59 +01:00